Manual de instrucciones SMC 8508T

Lastmanuals ofrece un servicio comunitario para compartir, de archivos en línea, de búsqueda de documentación relacionada con la utilización de materiales o programas: folleto, instrucciones, folleto de utilización, guía de instalación, manual técnico... ¡NO OLVIDES LEER LAS INSTRUCCIONES ANTES DE COMPRAR!

Si el contenido de este documento corresponde al folleto, instrucciones, lista de instrucción, de instalación o de utilización, al manual, al esquema de montaje o a la guía que compras, no dudes en telecargarlo. Lastmanuals te permite acceder fácilmente a la información de las instrucciones SMC 8508T. Esperamos que el manual SMC 8508T te sea útil.

Lastmanuals permite descargar las instrucciones SMC 8508T.


Mode d'emploi SMC 8508T
Download

Puedes descargar las siguientes instrucciones anexas a este producto:

   SMC 8508T (1467 ko)
   SMC 8508T annexe 1 (535 ko)
   SMC 8508T FICHE TECHNIQUE (357 ko)

Manual de resumen: instrucciones de uso SMC 8508T

Las instrucciones detalladas para la utilización aparecen en la Guía del usuario.

[. . . ] EZ Switch 10/100/1000 Manual de instrucciones De la gama EZ de soluciones LAN de bajo coste para grupos de trabajo de SMC Nº de publicación: 150000005200H R01 Septiembre de 2003 ÍNDICE Introducción . 9 Diagnóstico de los indicadores del switch . 11 Asignaciones de terminales 10BASE-T/100BASE-TX . 11 Asignaciones de terminales 1000BASE-T . [. . . ] 3 o superior, 100 m 100 ohmios UTP Cableado Cat. 3, 5e o 6, 100 m 100 ohmios UTP Tipo Conector RJ-45 RJ-45 RJ-45 Asignaciones de terminales 10BASE-T/ 100BASE-TX Precaución: NO enchufe conectores telefónicos en los puertos RJ-45. Use solamente cables de par trenzado con conectores RJ-45 que se adecuen a las normativas FCC. 1 8 8 1 Use cables de par trenzado, blindados (STP) o no (UTP), para las conexiones RJ-45: un cable de 100 ohmios de la categoría 3 o superior para las conexiones de 10 Mbps o un cable de 100 ohmios de la categoría 5 o superior para las conexiones de 100 Mbps. Asegúrese también de que la longitud de cualquier conexión de par trenzado no supere los 100 metros. 11 CABLES Dado que todos los puertos de este switch admiten el funcionamiento MDI/MDI-X automático, puede utilizar cables directos para todas las conexiones de red de los PC o servidores, o bien de otros switches o hubs. En los cables directos, los terminales 1, 2, 3 y 6 de un extremo del cable se conectan directamente con los terminales 1, 2, 3 y 6 del otro extremo. La siguiente tabla muestra los terminales del puerto MDI y 10BASE-T/100BASE-TX MDI-X. Terminal 1 2 3 6 4, 5, 7, 8 Nombre de la señal MDI-X Recibir datos más (RD+) Recibir datos menos (RD-) Transmitir datos más (TD+) Transmitir datos menos (TD-) No se utiliza a 10/100 Mbps Nombre de la señal MDI Transmitir datos más (TD+) Transmitir datos menos (TD-) Recibir datos más (RD+) Recibir datos menos (RD-) No se utiliza a 10/100 Mbps Asignaciones de terminales 1000BASE-T La siguiente tabla muestra los terminales del puerto MDI-X y 100BASE-T MDI. Estos puertos necesitan que estén conectados los cuatro pares de cables. Recuerde que para el funcionamiento de 1000BASE-T, los cuatros pares se utilizan tanto para transmitir como para recibir. Use un cable de par trenzado de 100 ohmios, blindado (STP) o no (UTP), de la categoría 5, 5e o 6 para las conexiones de 1000BASE-T. Sustituya todos los cables flexibles de la categoría 5 por cables de alto rendimiento de la categoría 5e o 6. Reduzca el número de conectores empleados en el enlace. Vuelva a conectar algunos conectores del enlace. 14 PRODUCT SPECIFICATIONS EZ Switch 10/100/1000 Standards Conformance IEEE 802. 3 IEEE 802. 3u IEEE 802. 3x IEEE 802. 3ab Communication Rate 10, 100, and 1000 Mbps Communication Mode Full or half duplex at 10/100 Mbps Full duplex at 1000 Mbps Media Supported 10BASE-T: 100-ohm Category 3 or better twisted-pair 100BASE-TX: 100-ohm Category 5 or better twisted pair 1000BASE-T: 100-ohm Category 5, 5e, or 6 twisted-pair Number of Ports SMC8505T: 5 RJ-45 1000BASE-T ports SMC8508T: 8 RJ-45 1000BASE-T ports Indicator Panel Power Ports: Link/Act, 1000M, 10/100M Dimensions 19. 64 x 11. 65 x 3. 66 cm, (7. 76 x 4. 6 x 1. 44 in) Weight SMC8505T: 0. 59 kg (1. 309 lbs) SMC8508T: 0. 62 kg (1. 378 lbs) MAC Address Table 8 K entries 15 PRODUCT SPECIFICATIONS Memory Buffer 768 Kbits per unit Power Consumption SMC8505T: 12 Watts SMC8508T: 15 Watts Power Requirement DC input SMC8505T: 12 V, 1 A SMC8508T: 12 V, 1. 25 A Temperature Operating: 0 ~ 40 ºC / 32 ~ 98 ºF Storage: -40 ~ 70 ºC / -40 ~ 158 ºF Humidity 10% to 90% non-condensing EMC/Safety Compliances CE Mark Immunity EN 61000-4-2/3/4/5/6/8/11 Emissions FCC Class B, CISPR Class B, EN 61000-3-2/3 Safety CSA (UL1950, CSA 22. 2. 950), TUV/GS (EN60950) 16 COMPLIANCES FCC - Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient the receiving antenna · Increase the separation between the equipment and receiver · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected · Consult the dealer or an experienced radio/TV technician for help EC Conformance Declaration - Class B SMC contact for these products in Europe is: SMC Networks Europe, Edificio Conata II, Calle Fructuós Gelabert 6-8, 2o, 4a, 08970 - Sant Joan Despí, Barcelona, Spain. This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the compliance with these Directives, the following standards were applied: RFI Emission: · Limit class B according to EN 55022:1998, IEC 60601-1-2 (EMC, medical) · Limit class A for harmonic current emission according to EN 61000-3-2/1995 · Limitation of voltage fluctuation and flicker in low-voltage supply system according to EN 61000-3-3/1995 Immunity: · Product family standard according to EN 55024:1998 · Electrostatic Discharge according to EN 61000-4-2:1995 (Contact Discharge: ±4 kV, Air Discharge: ±8 kV) i COMPLIANCES · Radio-frequency electromagnetic field according to EN 61000-4-3:1996 (80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m) · Electrical fast transient/burst according to EN 61000-4-4:1995 (AC/DC power supply: ±1 kV, Data/Signal lines: ±0. 5 kV) · Surge immunity test according to EN 61000-4-5:1995 (AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV) · Immunity to conducted disturbances, Induced by radio-frequency fields: EN 61000-4-6:1996 (0. 15 - 80 MHz with 1 kHz AM 80% Modulation: 3 V/m) · Power frequency magnetic field immunity test according to EN 61000-4-8:1993 (1 A/m at frequency 50 Hz) · Voltage dips, short interruptions and voltage variations immunity test according to EN 61000-4-11:1994 (>95% Reduction @10 ms, 30% Reduction @500 ms, >95% Reduction @5000 ms) LVD: MDD: · EN 60950 (A1/1992; A2/1993; A3/1993; A4/1995; A11/1997) · IEC 60601-1 Industry Canada - Class B This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled "Digital Apparatus" ICES-003 of the Department of Communications. Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe B prescrites dans la norme sur le matériel brouilleur: « Appareils Numériques » NMB-003 édictée par le ministère des Communications. Safety Compliance CSA/NRTL (C22. 2. 950, UL 1950) EN60950, (IEC 950) ii COMPLIANCES Wichtige Sicherheitshinweise (Germany) 1. Bitte lesen Sie diese Hinweise sorgfältig durch. Heben Sie diese Anleitung für den späteren Gebrauch auf. Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. [. . . ] Products returned to SMC should have any customer-installed accessory or add-on components, such as expansion modules, removed prior to returning the product for replacement. SMC is not responsible for these items if they are returned with the product. Customers must contact SMC for a Return Material Authorization number prior to returning any product to SMC. Any product returned to SMC without a valid Return Material Authorization (RMA) number clearly marked on the outside of the package will be returned to customer at customer's expense. [. . . ]

CONDICIONES PARA DESCARGAR LAS INSTRUCCIONES SMC 8508T

Lastmanuals ofrece un servicio comunitario para compartir, de archivos en línea, de búsqueda de documentación relacionada con la utilización de materiales o programas: folleto, instrucciones, folleto de utilización, guía de instalación, manual técnico...
En ningún caso, Lastmanuals será responsable si el documento que has buscado no está disponible, está incompleto, en otro idioma diferente del tuyo o si la designación y el idioma no corresponden. Lastmanuals no se ocupa de las traducciones.

Para descargar las instrucciones SMC 8508T, haz clic en "Descargar las instrucciones" si aceptas los términos del presente contrato.

Buscar una instrucción

 

Copyright © 2015 - LaInstrucciones - Reservados todos los derechos
Los nombres y las marcas citadas pertenecen a sus respectivos propietarios.

flag